What We Do

Engineering Services

From design to commissioning, from maintenance to technical training — a complete automation solution.

01 / Design

Panel Design

Professional electrical schematic preparation fully compliant with IEC 61439 standards using EPLAN Electric P8 software. Customised, approved engineering deliverables tailored to the customer's specification.

  • Single-line and multiwire schematic preparation with EPLAN
  • IEC 61439-compliant component selection and bill of materials
  • 3D panel layout planning
  • Customer approval process management
  • Revision handling and as-built documentation
Panel Design
Tools Used
EPLAN Electric P8
AutoCAD Electrical
IEC 61439 Standard Set
Siemens SIRIUS / Schneider Acti9 Catalogues
Assembly & Wiring
Assembly Scope
DIN rail cutting and mounting
Cable duct system installation
IEC colour-coded wiring and ferrule terminals
PE / N grounding system
IP protection class testing
02 / Assembly

Assembly & Wiring

Professional assembly and wiring to DIN standards, matching the schematic exactly. Every terminal numbered, every cable labelled, grounding system fully implemented.

  • Schematic conformity verification
  • IP54 / IP65 gland and cable fitting installation
  • Torque check under load
03 / Commissioning

Commissioning

Full functional testing at the factory, site integration and PLC programming. Every panel undergoes a Factory Acceptance Test (FAT) before delivery; the test report is provided to the customer.

  • PLC software upload and parameter configuration
  • I/O testing — every input/output verified individually
  • Factory Acceptance Test (FAT) and protocol sign-off
  • Site commissioning and system integration testing
  • Operator training and user manual delivery
Commissioning
PLC Platforms
Siemens S7-300 / S7-400 / S7-1200 / S7-1500
Allen-Bradley CompactLogix / ControlLogix
Schneider Electric Modicon M340 / M580
WinCC / FactoryTalk / Vijeo Designer HMI
Maintenance & Service
Maintenance Scope
Annual periodic maintenance contract
Thermographic measurement (hot-spot detection)
Connection inspection and torque check
Fault diagnosis and emergency response
Spare parts supply and stock management
04 / Maintenance

Maintenance & Service

2-year post-delivery warranty coverage and optional annual maintenance contracts ensure uninterrupted production continuity. On-site service throughout Turkey.

  • 2-year manufacturing warranty
  • Annual periodic maintenance contract
  • Emergency service across Turkey
  • PLC software updates and backup
05 / Fire Suppression

Wet Fire Suppression Systems

The control and monitoring panels we design for sprinkler, hydrant and deluge systems are fully compliant with NFPA 20 and TS EN 12845 standards. From pump control panels to pressure monitoring systems, the complete electrical infrastructure is designed on a project basis and commissioned on site.

  • Fire pump control panel (jockey + main pump)
  • Pressure switch and flow switch monitoring
  • Fire alarm panel integration
  • UPS-backed uninterruptible power supply
  • CE-compliant, delivered with test report
Wet Fire Suppression
Application Areas
Factories and industrial facilities
Warehouses and logistics centres
Shopping centres and office buildings
Hospitals and public buildings
Foam Fire Suppression
System Components
Foam concentrate dosing unit control
Flow rate and pressure monitoring panels
Automatic/manual activation control
SCADA integration and remote monitoring
06 / Fire Suppression

Foam Fire Suppression Systems

We design the electrical control infrastructure for foam-based fire suppression systems for facilities with flammable liquid risks such as petroleum, chemical and solvent storage. These high-reliability systems include redundant control architecture and a continuous self-test function as standard.

  • ATEX zone classification-compliant hardware selection
  • Redundant control system (backup PLC)
  • Gas/smoke detector integration
  • Remote testing and alarm management
07 / SCADA & Automation

SCADA & Automation Systems

Manage all your facility processes from a single screen with SCADA systems developed on Siemens, Schneider and Allen-Bradley platforms. Real-time data monitoring, alarm management, trend analysis and reporting modules provide full visibility across your production processes. A complete solution including Industrial Ethernet and Profibus/Profinet network infrastructure is offered.

  • PLC programming (Siemens TIA Portal, Codesys)
  • HMI screen design and software
  • Remote access and mobile monitoring
  • OPC-UA / Modbus / Profinet integration
  • Production data reporting (MES integration)
SCADA & Automation
Supported Platforms
Siemens S7-300 / S7-1200 / S7-1500
Schneider Modicon M340 / M580
Allen-Bradley ControlLogix / CompactLogix
WinCC / Ignition / Indusoft SCADA software
Grounding & Lightning Protection
Service Scope
Soil resistivity measurement (Wenner method)
Facility-wide equipotential bonding plan
Lightning protection risk analysis and design report
Measurement protocol and test certificate
08 / Grounding

Grounding & Lightning Protection Systems

We provide facility grounding design, installation and measurement services in accordance with TS EN 62305 and TS HD 60364 standards. The process begins with soil resistivity analysis and covers the selection of strip, plate or deep grounding electrodes, a facility-wide equipotential bonding system, and lightning protection zone calculations — a comprehensive engineering service.

  • TS EN 62305-compliant lightning protection
  • Low-voltage surge protection device (SPD) selection and placement
  • Equipotential busbar and conductor sizing
  • Periodic earth resistance measurement and reporting
09 / Electrical Installation

Industrial Electrical Installation

We carry out low-voltage electrical installation work for factories, warehouses, large-scale commercial buildings and infrastructure projects in accordance with TS HD 60364 standards. From cable selection and sizing to containment systems, from lighting design to grounding installation, the complete infrastructure is delivered in full; after handover, leakage current and insulation resistance measurements are performed and the protocol is provided to the customer.

  • Power and lighting installation (TS HD 60364)
  • Medium-voltage transformer connection and LV distribution
  • LED industrial lighting design and installation
  • Insulation resistance and leakage current measurement
  • Electrical internal installation design
Industrial Electrical Installation
Project Types
Organised industrial zone plot connection
Factory expansion and renovation wiring
Cold storage and production line installation
Lighting energy efficiency retrofit

Quote → Delivery Process

1
Quote
2
Order
3
Design
4
Manufacturing
5
FAT
6
Delivery
7
Commissioning
8
Warranty

Let's Talk About Your Project

Share your requirements and we'll provide the best solution for you.

Get in Touch
Get in Touch